DRAWMER S3 OPERATOR’S MANUAL
CHAPTER 3
IF A FAULT DEVELOPS
For warranty service please call Drawmer Electronics Ltd. or
their nearest authorised service facility, giving full details of
the difficulty.
A list of all main dealers can be found on the Drawmer
webpages.
On receipt of this information, service or shipping instructions
will be forwarded to you.
No equipment should be returned under the warranty without
prior consent from Drawmer or their authorised representative.
For service claims under the warranty agreement a service
Returns Authorisation (RA) number will be issued.
Write this RA number in large letters in a prominent position
on the shipping box. Enclose your name, address, telephone
number, copy of the original sales invoice and a detailed
description of the problem.
Authorised returns should be prepaid and must be insured.
All Drawmer products are packaged in specially designed
containers for protection. If the unit is to be returned, the original
container must be used. If this container is not available, then
the equipment should be packaged in substantial shock-proof
material, capable of withstanding the handling for the transit.
CONTACTING DRAWMER
Drawmer Electronics Ltd., will be pleased to answer all
application questions to enhance your usage of this
equipment. Please address correspondence to:
Drawmer (Technical Help line)
Coleman Street
Parkgate
Rotherham
S62 6EL
UK
Alternatively contact us by E-mail on :
for sales enquiries: sales@drawmer.com
or for technical issues: tech@drawmer.com
Further information on all Drawmer dealers, Authorised service
departments and other contact information can be obtained
from our web pages on:
http://www.drawmer.com
GENERAL INFORMATION
INPUT
Input Impedance 600 Ohms or greater
Maximum Input Level +30dBu
OUTPUT
Output Impedance 600 Ohms
Maximum Output Level +30dBu @ 10k Ohms Load
+26dBu @ 600 Ohms Load
FREQUENCY RESPONSE
<24Hz to 38kHz -1dB
<10Hz to 60kHz -3dB
CROSSTALK < -80dB @ 10kHz
< -74dB @ 20kHz
NOISE AT UNITY GAIN
with flat EQ response switched in circuit
Wideband 22Hz - 22kHz
AV -79dB -84dB
-87dB -94dB
S3 THREE-BAND STEREO VACUUM TUBE COMPRESSOR
DATA SPECIFICATION
% DISTORTION (THD & NOISE) @ 1kHz
0dB (ref +4) 0.03%
10dB (ref +4) 0.1%
20dB (ref +4) 0.4%
POWER REQUIREMENTS
230Volt or 115V at 50-60hZ, 60VA
FUSE RATING
T500mA for 230Volt, T1A for 115Volt
Conforming to IEC 127-2
FUSE TYPE
20mm x 5mm, Class 3 Timed-Blo, 250Volt working
CASE SIZE
482mm (W) x 132mm (H) x 315mm (D)
WEIGHT 9.7Kgs